Skip to navigation

experiments

Microscale extraction of copper

Copper oxide can be reduced to copper using hydrogen. This reaction is usually done as a large scale demonstration, but this microscale version can be done by students. This can be used to show the relative positions of copper and hydrogen in the reactivity series and can also be used for percentage yield-type calculations.

Read our standard health & safety guidance

Lesson organisation

This practical involves some specialist microscale equipment such as a comboplate® with lids and a microburner. If this equipment is available in your institution this is a good practical to do. It is probably not worth buying the equipment in specially. If students are familiar with the equipment then this takes only a few minutes to set up and run. For students who are not it could take a lot longer.

There is a danger of the glass breaking when inserting the glass tube into the silicone tubing. Warn students of this and show them how to hold the glass tube near the end that they are attaching to the silicone tube so as to minimise the risk. Technicians can do this.

This practical may not be appropriate for all classes as it involves putting 2 mol dm-3 acid into a syringe. Teachers should consider whether their employers risk assessment needs modification for the class doing this experiment.

Students should be warned about the dangers of the ethanol in the microburners. They should keep the burner upright and should not take off the lid. Ethanol can catch fire very easily and produces highly flammable vapour. To minimise any risk, ensure that the burners are filled prior to the lesson. Students need to light their burners and the easiest way to do this is with matches. It is probably advisable to have a box of matches per bench, to know how many you have and to count them in and out at the start and end of the session. Having a limited number of matches in each box reduces the potential for mischief. As an alternative, have a lit Bunsen burner or two in the laboratory and have students use splints to light their burners. However, they can be a little tricky to light this way.

Students should wear eye protection throughout this practical.

Apparatus and chemicals

Eye protection

Each student or pair of students requires:

Comboplate®, 1 (see note 1)
Syringe (2 cm3)
Lid number 1
Lid number 2
Short lengths silicone tubing, 2
Piece of glass tubing (10 cm) – of a width to match the silicone tubing
Matches
If students are calculating percentage yield, they also need access to a balance which reads to two decimal places
Microburner filled with ethanol (Highly flammable), or
Industrial denatured alcohol, IDA (Highly flammable, Harmful) (see note 1)

Copper(II) oxide (Harmful)
Magnesium ribbon (Low hazard), 3 cm
Hydrochloric acid, 2 mol dm-3 (Irritant at this concentration), about 2 cm3

Technical notes

Ethanol (Highly flammable)or
Industrial denatured alcohol, IDA (Highly flammable, Harmful)Refer to CLEAPSS Hazcard 40A
Copper(II) oxide (Harmful) Refer to CLEAPSS Hazcard 26
Magnesium ribbon (Low hazard) Refer to CLEAPSS Hazcard 59A
Hydrochloric acid (Irritant at concentration used) Refer to CLEAPSS Hazcard 47A and Recipe card 31

1 Microscale equipemt can be sourced on the internet. Philip Harris (www.philipharris.co.uk) has a range of suitable equipment.

2 The microburners should be filled with ethanol or IDA for the students prior to the start of the practical work.

Procedure

HEALTH & SAFETY: Wear eye protection

a Attach a piece of silicone tubing to both lids.

b Half fill well F1 with tap water and attach lid number 2.

c Gently coil the magnesium ribbon to fit into well F6 and attach lid number 1.

d Fill well E6 with hydrohloric acid.

e Dip the end of the glass tubing into the pot of copper oxide and collect some in the end of the tube. Gently tap the tube to get the copper oxide more or less into the middle.

f Holding the glass tube near the end you are attaching, fix each end to the silicone tubing attached to the lids (see diagram).

Microscale extraction of copper

g Fill the syringe carefully with acid from well E6, attach the syringe to the lid on well F6, and add a drop or two to the magnesium to get it fizzing. You will see if the hydrogen is flowing through the system as it produce bubbles in the water in well F1. You need to add enough acid throughout the experiment to keep a slow but steady stream of bubbles.

h Light the microburner and begin to heat the copper oxide in the tube. Keep heating for a minute or two and watch for changes occurring in the tube. When there are no more changes, stop heating, wait for a moment, and then try to light the gas coming out of well F1. Blow out the microburner and detach the lids from the comboplate®.

i When the tube has cooled, tap the end gently on a piece of rough paper to extract the product.

Teaching notes

The magnesium reacts with the acid to produce hydrogen. As the copper oxide is heated it reacts with the hydrogen and is reduced, producing copper and water. The black copper oxide at the start turns to orange copper (this could be tested with a circuit tester once it has been removed from the tube) and a liquid which is water can be seen at the end of the tube. Lighting the gas coming out of the lid should convince students that it is hydrogen as it produces the expected ‘squeaky pop’.

Copper oxide + hydrogen → copper + water

CuO + H2 → Cu + H2O

If you want students to calculate the percentage yield, they need to weigh the glass tube at the start, with the copper oxide in it, and at the end with the copper. If there appears to be a greater than 100% yield, this is probably due to there still being copper oxide present alongside the copper. Alternatively, students can remove the copper from the tube prior to weighing it and attempt to separate out the copper from the copper oxide. This gives a lower yield (neither is particularly accurate.)

Health and Safety checked, February 2008

Web links

For a video demonstration of how to do the larger scale demonstration version see http://media.rsc.org/videoclips/demos/Reductioncopperoxide.wmv

Updated 29 Oct 2008

Average rating: 4 out of 5

Your reviews

Literature review?

Submitted by: treasure on 1 November 2009

Review this experiment




69883

To avoid spamming of our site please enter the generated 5 character code above.


Your rating: (1 Poor - 5 Good)


review this page | | print this page

Home » Experiments » Intermediate » Oxidation and reduction » Microscale extraction of copper